New Hospital Ophthalmic Pachymeter& Biometer-Scan Probe for Eye exams: ACD, Lens, Vitreous Ultrasound Scanner : SIFULTRAS-8.25

$3,500.00 $2,999.00

Ophthalmic AP-Scan/ Biometer and Pachymeter

Probe frequency:  10MHz/20MHz

Examination modes: Normal, Aphakic, pseudophakic and dense cataract

Built-in thermal printer,information output conveniently.

Internal optional battery, practical for out-clinic diagnose

Display:   5.7 inch color touch LCD screen.

 

New Hospital Ophthalmic Pachymeter&A-Scan Probe for Eye exams: ACD, Lens, Vitreous Ultrasound Scanner : SIFULTRAS-8.25

 

Description:

A-scan is suitable for measuring the anterior chamber depth, lens thickness, vitreous body length, axial length and calculating the IOL power for an implanted lens.

P-scan is suitable for measuring the corneal thickness.The expected service life of SIFULTRAS-8.24 AP ophthalmological ultrasonic measuring instruments is 10 years. And also with the central area and the peripheral areas gain automatic compensation capability, accurate measurement of central and peripheral corneal thickness, is widely used in the preoperative examination and postoperative effect evaluation of refractive surgery.

A-scan probe and P-scan probe, which is used to measure axial length and corneal thickness.SIFULTRAS-8.24  ophthalmological ultrasonic measuring instruments have been used in medical institutions clinical ophthalmology for measuring axial length biological parameters and corneal thickness. What’s more, It is suitable for over one age population, weight has no limit.

 

A scan probe

A. Probe Frequency: 10 Mhz
B. Resolution: 0.01mm
C. Accuracy: ±0.02mm
D. Gain adjustable: 0-120dB
E. Measurement range: 15~35 mm (vel 1640m/s)
F. Measurements: ACD, Lens, Vitreous, and AXL
G. Examination modes: Normal, Aphakic, pseudophakic and dense cataract
H. Measurement mode: immersion and contact , auto and manual
I. IOL formulas: SRK-II,SRK-T,BINKHORST,HOLLADAY,HOFFER-Q,HAIGIS

 

Pachymeter Scan : 

  •  Probe frequency: 20 Mhz.
  •  Resolution: 1um.
  •  Measurement range: 0.23~1.3mm.
  •  Accuracy: ±5um.

 

 

Paremeters: 
1. Triangular model, portable and firm.
2. 5.7 “inch color LED touch screen.
3. Standard workstation software, easily for transfer and manage data.
4. Free software upgrade via USB interface.
5. Built-in thermal printer,information output conveniently.
6. Internal optional battery, practical for out-clinic diagnose.

 

 

Technical Specifications:

Pachymeter/A-Scan

Model: SIFULTRAS-8.25

Power Requirement :   AC 100-240V      50-60Hz

Rated input: DC12V   3.0A

Dimension:  200*168*165(mm, L*W*H)

Weight: of main Unit approx: 1.7Kg (exclude the accessories)

 

Standard configuration:

1 Main unit.
2
10.0MHz A probe.
3 Adapter.
4 Gage block for calibration.
5 Touch screen pen.

Optional Configuration:

1 Lithium battery
2 Battery charger.
3 Footswitch
4 Prager shell for Immersion

 

>Certifications 

CE
ISO13485
This product is not to be used in  THE US .